A COMPARATIVE STUDY OF VIBRATION CONTROL IN CANTILEVER BEAM AND U-TUBE CORIOLIS MASS FLOW METER USING LAB VIEW
Aravind Sharma , Professor, Instrumentation And Control Engineering, Saranathan College Of Engineering, India Sachin Prabhakarn , Professor, Instrumentation And Control Engineering, Saranathan College Of Engineering, IndiaAbstract
Vibration is a significant issue in flow measurement devices that can lead to inaccurate measurements. This paper presents a comparative study of vibration control in two common flow measurement devices, a cantilever beam and a U-tube Coriolis mass flow meter. The study uses LabVIEW software to control and measure vibration levels in each device. Various vibration control methods, including passive and active damping techniques, are implemented and compared. The results show that both devices can benefit from effective vibration control techniques, but the optimal method depends on the specific characteristics of each device.
Keywords
vibration control, cantilever beam, U-tube Coriolis mass flow meter
References
QiaoShaojie, Wang Shuai, ZhengDezhi, Fan Shangchun-Analysis and Suppression of Mechanical
Coupling Vibrations of Coriolis Mass Flowmeter2010 International Conference on Intelligent
Computation Technology and Automation978-0-7695-4077-1/10 $26.00 © 2010 IEEEDOI
1109/ICICTA.2010.213
Yao Kai, Zhao Jianhui, Li FanFinite Element Analysis of the Influence of Vibration Disturbance on
Coriolis Mass Flow Meters2010 International Conference on Intelligent Computation Technology and
Automation978-0-7695-4077-1/10 $26.00 © 2010 IEEEDOI 10.1109/ICICTA.2010.213
Liu Shigang1, Xie Dailiang1*, Tao Shan2Design and Simulation of Fluidic Flowmeter for the
Measurement of Liquid Flow inMicrochannelElectromagnetic2012 Third International Conference on
Digital Manufacturing & Automation
Arunshankarjayabalan ,Umapathy,Sliding mode controller with multi sensor data fusion for Peizo
actuated structure,2011 –Rasearch gate
KV Gangatharan ,Arun P ParameshvaranParametric modelling and FPGA based real time active
vibration control of a peizo electric laminate cantilever beam at resonance -2014-Reasearch gate
F J Arnold , RL XiemenesR.Aruthur , S SMuhlenA Driver for Peizo electric transducer with control of reasonance- -2015-science direct
Ahmed A , Ali Rana Abdul Rahman lateel Mohamed waelsaseedIntelligent tunning of vibration
mitigation process for single link manipulation using fuzzy logic 2017-science direct
ReissomWeldigiorgis ,Prasad Krishna , K V GangatharanVibration control of a smart cantilever beam using srain rate feedback 2014 –science direct
Asan Gain A labview based data acquisition systems for vibration monitoring and analysis 2002-
SCRND
JozeKutin, Andrej smercnik , Ivan BajsicPhase locking control of the coriolis meter ‘s resonance frequency based on virtual instrumentation-2003 science direct