Abstract

Vibration is a significant issue in flow measurement devices that can lead to inaccurate measurements. This paper presents a comparative study of vibration control in two common flow measurement devices, a cantilever beam and a U-tube Coriolis mass flow meter. The study uses LabVIEW software to control and measure vibration levels in each device. Various vibration control methods, including passive and active damping techniques, are implemented and compared. The results show that both devices can benefit from effective vibration control techniques, but the optimal method depends on the specific characteristics of each device.

Keywords

vibration control, cantilever beam, U-tube Coriolis mass flow meter

References

QiaoShaojie, Wang Shuai, ZhengDezhi, Fan Shangchun-Analysis and Suppression of Mechanical

Coupling Vibrations of Coriolis Mass Flowmeter2010 International Conference on Intelligent

Computation Technology and Automation978-0-7695-4077-1/10 $26.00 © 2010 IEEEDOI

1109/ICICTA.2010.213

Yao Kai, Zhao Jianhui, Li FanFinite Element Analysis of the Influence of Vibration Disturbance on

Coriolis Mass Flow Meters2010 International Conference on Intelligent Computation Technology and

Automation978-0-7695-4077-1/10 $26.00 © 2010 IEEEDOI 10.1109/ICICTA.2010.213

Liu Shigang1, Xie Dailiang1*, Tao Shan2Design and Simulation of Fluidic Flowmeter for the

Measurement of Liquid Flow inMicrochannelElectromagnetic2012 Third International Conference on

Digital Manufacturing & Automation

Arunshankarjayabalan ,Umapathy,Sliding mode controller with multi sensor data fusion for Peizo

actuated structure,2011 –Rasearch gate

KV Gangatharan ,Arun P ParameshvaranParametric modelling and FPGA based real time active

vibration control of a peizo electric laminate cantilever beam at resonance -2014-Reasearch gate

F J Arnold , RL XiemenesR.Aruthur , S SMuhlenA Driver for Peizo electric transducer with control of reasonance- -2015-science direct

Ahmed A , Ali Rana Abdul Rahman lateel Mohamed waelsaseedIntelligent tunning of vibration

mitigation process for single link manipulation using fuzzy logic 2017-science direct

ReissomWeldigiorgis ,Prasad Krishna , K V GangatharanVibration control of a smart cantilever beam using srain rate feedback 2014 –science direct

Asan Gain A labview based data acquisition systems for vibration monitoring and analysis 2002-

SCRND

JozeKutin, Andrej smercnik , Ivan BajsicPhase locking control of the coriolis meter ‘s resonance frequency based on virtual instrumentation-2003 science direct

Article Statistics

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Copyright License

Download Citations

How to Cite

Aravind Sharma, & Sachin Prabhakarn. (2023). A COMPARATIVE STUDY OF VIBRATION CONTROL IN CANTILEVER BEAM AND U-TUBE CORIOLIS MASS FLOW METER USING LAB VIEW. European International Journal of Multidisciplinary Research and Management Studies, 3(05), 49–53. https://doi.org/10.55640/eijmrms-03-05-09